TOPSCIEN Variable Volume Micropipettes are product of intensive ergonomic and operational studies and the application of modern innovative materials . They are the perfect manual pipettes for demanding laboratory applications for scientists who prefer central pipetting buttons .
The Micropipettes provide all of the features required by users working in the Iife sciences field.
Robust , One-handed operation , Easy calibration institutions , completely auto clavable , high precision and Easy Calibration technique for lasting reliability .
Features :
Large central pipetting button and separate ejection function
True one-handed operation for both right-and left-handers
Completely autoclavable at 121℃ ( 20 min ) volume-change protection
4-Position volume display , always clearly visible Easy Calibration technique- readjustment without Special tools
Changes from factory settings are clearly visible extemally .
Short stroke of only 12.5 mm to reduce the risk of RSI ( Repetitive Strain Injury )
Corrosion-resistant piston and ejector
Color-coded for easy selection of the right tip CE-compliant
P Series Variable Volume Single Channel Micropipette (121℃ autoclavable)
Cat.No. |
Code.No. |
Volume
μl |
Increment
μl |
A*≤±% |
CV*≤% |
8011179 |
TP1H |
0.1-1μl |
(0.001ul) |
2 |
1.2 |
8011180 |
TP10H |
0.5-10μl |
(0.01ul) |
1 |
0.5 |
8011181 |
TP20H |
2-20μl |
(0.02ul) |
0.8 |
0.4 |
8011182 |
TP100H |
10-100μl |
(0.1ul) |
0.6 |
0.2 |
8011183 |
TP200H |
20-200μl |
(0.2ul) |
0.6 |
0.2 |
8011184 |
TP1000H |
100-1000μl |
(1ul) |
0.6 |
0.2 |
8011185 |
TP5000H |
500-5000μl |
(5ul) |
0.6 |
0.2 |
8011186 |
TP10000H |
1000-10000μl |
(10ul) |
0.6 |
0.2 |
P Series Variable Volume Single Channel Micropipette ( Ejector 121℃ autoclavable)
Cat.No. |
Code.No. |
Volume
μl |
Increment
μl |
A*≤±% |
CV*≤% |
8011189 |
TP1 |
0.1-1μl |
(0.001ul) |
2 |
1.2 |
8011190 |
TP10 |
0.5-10μl |
(0.01ul) |
1 |
0.5 |
8011191 |
TP20 |
2-20μl |
(0.02ul) |
0.8 |
0.4 |
8011192 |
TP100 |
10-100μl |
(0.1ul) |
0.6 |
0.2 |
8011193 |
TP200 |
20-200μl |
(0.2ul) |
0.6 |
0.2 |
8011194 |
TP1000 |
100-1000μl |
(1ul) |
0.6 |
0.2 |
8011195 |
TP5000 |
500-5000μl |
(5ul) |
0.6 |
0.2 |
8011196 |
TP10000 |
1000-10000μl |
(10ul) |
0.6 |
0.2 |
Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation
|