Easy Handling
A particular advantage of the new multichannel pipette is the easy operation , e.g., when performing serial pipetting of immunological assays , while making serial dilutions or when filling 96-well plates for cell cultures . Use the Innovative material will be more lighter . Pipetting easy and convenient
Reduce the risk for hands injury when repetitive pipetting .
It can be operated comfortably whether large hands or small hands ,
The ergonomiCelly finger rest takes the load off the hand , not need to grip the pipette tightly , so the pipetting operations can be completed with the fatigue . True one-hand operated
The one hand can be change the volume and fix the volume easyly and conveniently .
The large pipetting button will be saved pipetting strength .
Pisto n corrosion proof
Lightweight-Accurate-low force
The piston-operated Micropipettes provides maximum versatility and optimum quality over the entire volume range.
There are 5 different volume 8 and 12chennels micropipette which the volume cover 0.5-300ul
Features :
The TOPSCIEN multichannel Micropipette have the Iight weigh,operated with light pipetting strength and easily and conveniently .
High chemical and UV resistance
Fully autoclavable
Rotating dispensing head for optimal pipetting Convenience .
Due to the optimized standard design for the tip cone which it can be compatible with a wide range band of tips
A central pipetting button, the one-handed operation, precise 4-position volume settings and a volume display that can be easily read by both right- and left-handed operators are only a few examples of the attention to detail in the design of the TOPSCIEN Variable Volume Micropipette
P Series Variable Volume 8 Channel Micropipette (121℃ autoclavable )
Cat.No |
Code. No. |
Volume |
Volume range
μl |
Volume step
μl |
A*≤±% |
CV*≤% |
Increment
μl |
Type of tips
μl |
8011260 |
TP8D10H |
0.5-10 |
10/5/1 |
1.6/2/8 |
1.0/2/6 |
0.01 |
20 |
8011261 |
TP8D50H |
5-50 |
50/25/5 |
0.8/1.4/6 |
0.4/0.8/3 |
0.05 |
200 |
8011262 |
TP8D100H |
10-100 |
100/50/10 |
0.8/1.4/4 |
0.3/0.6/2 |
0.1 |
200/300 |
8011263 |
TP8D200H |
20-200 |
200/100 /20 |
0.8/1.4/4 |
0.3/0.6/1.5 |
0.2 |
200/300 |
8011264 |
TP8D300H |
30-300 |
300/150/30 |
0.6/1.2/3 |
0.3/0.6/1.5 |
0.3 |
300 |
P Series Variable Volume 8 Channel Micropipette( Ejector 121℃ autoclavable)
Cat.No |
Code. No. |
Volume
|
Volume range
μl |
Volume step
μl |
A*≤±% |
CV*≤% |
Increment
μl |
Type of tips
μl |
8011270 |
TP8D10 |
0.5-10 |
10/5/1 |
1.6/2/8 |
1.0/2/6 |
0.01 |
20 |
8011271 |
TP8D50 |
5-50 |
50/25/5 |
0.8/1.4/6 |
0.4/0.8/3 |
0.05 |
200 |
8011272 |
TP8D100 |
10-100 |
100/50/10 |
0.8/1.4/4 |
0.3/0.6/2 |
0.1 |
200/300 |
8011273 |
TP8D200 |
20-200 |
200/100 /20 |
0.8/1.4/4 |
0.3/0.6/1.5 |
0.2 |
200/300 |
8011274 |
TP8D300 |
30-300 |
300/150/30 |
0.6/1.2/3 |
0.3/0.6/1.5 |
0.3 |
300 |
P Series Variable Volume 12 Channel Micropipette (121℃ autoclavable )
Cat.No |
Code. No. |
Volume
|
Volume range
μl |
Volume step
μl |
A*≤±% |
CV*≤% |
Increment
μl |
Type of tips
μl |
8011280 |
TP12D10H |
0.5-10 |
10/5/1 |
1.6/2/8 |
1.0/2/6 |
0.01 |
20 |
8011281 |
TP12D50H |
5-50 |
50/25/5 |
0.8/1.4/6 |
0.4/0.8/3 |
0.05 |
200 |
8011282 |
TP12D100H |
10-100 |
100/50/10 |
0.8/1.4/4 |
0.3/0.6/2 |
0.1 |
200/300 |
8011283 |
TP12D200H |
20-200 |
200/100 /20 |
0.8/1.4/4 |
0.3/0.6/1.5 |
0.2 |
200/300 |
8011284 |
TP12D300H |
30-300 |
300/150/30 |
0.6/1.2/3 |
0.3/0.6/1.5 |
0.3 |
300 |
P Series Variable Volume 12 Channel Micropipette( Ejector 121℃ autoclavable)
Cat.No |
Code. No. |
Volume
|
Volume range
μl |
Volume step
μl |
A*≤±% |
CV*≤% |
Increment
μl |
Type of tips
μl |
8011290 |
TP12D10 |
0.5-10 |
10/5/1 |
1.6/2/8 |
1.0/2/6 |
0.01 |
20 |
8011291 |
TP12D50 |
5-50 |
50/25/5 |
0.8/1.4/6 |
0.4/0.8/3 |
0.05 |
200 |
8011292 |
TP12D100 |
10-100 |
100/50/10 |
0.8/1.4/4 |
0.3/0.6/2 |
0.1 |
200/300 |
8011293 |
TP12D200 |
20-200 |
200/100 /20 |
0.8/1.4/4 |
0.3/0.6/1.5 |
0.2 |
200/300 |
8011294 |
TP12D300 |
30-300 |
300/150/30 |
0.6/1.2/3 |
0.3/0.6/1.5 |
0.3 |
300 |
Calibrated to deliver (TD. Ex) Error limits according to the nominal capacity (=maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20℃,and with smooth, steady operation The error limits are within the limits of DIN EN IS0 8655-2. Conformity certified to DIN 12
600.A=Accuracy, CV =Coefficient of variation
|